Coolant Distribution Unit (CDU)
Designed to deliver safe, efficient, and scalable liquid cooling for today’s most demanding AI and HPC applications.
Up to 800kW
24/7 redundacy
Customizable solutions
Designed to cool high-density data centre reliably, at scale
Exceptional partial Power Usage Effectiveness (pPUE) of 1,02, for energy-efficient cooling.
Precise temperature, flow and pressure control.
Modular design for data centre growth.
Reliable operation with redundant pump.
Local network scalable to multiple units.
Easy access for maintenance operations.
CDU’s key features
High-efficiency heat exchanger
Advanced brazed plate heat exchangers to transfer heat from the secondary loop to the building’s chilled water system.
Precision pressure control
Integrated variable-speed pumps and smart pressure regulation ensure consistent coolant delivery, adapting to changing thermal loads.
Redundancy and reliability
Designed for 24/7 operation, CDU includes redundant pumps, power supplies, sensors and failover systems to ensure uninterrupted cooling.
Compact and modular design
In-row or in-room configurations with variable connection positions for high flexibility in new buildings or retrofits.
Real time monitoring and diagnostics
Precise advanced Modbus control and built-in sensors for real-time monitoring and leak detection.
Easily control all operating parameters thanks to a wide touch screen display.
Temperature / Pressure / Flow rate / Water level / Alarms
Wide capacity range to meet the needs of AI and HPC applications (400-800kW)
Advanced thermal management for high-density environments
Supports direct‑to‑chip and immersion cooling systems.
Hydraulic separation between facility loop and IT loop for a precise cooling.
Controlled supply temperature and redundant pumping.
Easy integration with chillers.
1. Outdoor chiller. / 2. CDU. / 3. Server racks (field supplied)
CDU and free cooling chillers: complete solution for edge data centres
Compact design for modular container environments, ensuring optimal footprint without compromising performance.
Stable temperature, cooling redundancy, and a rapid response to fluctuating workloads ensure operational reliability to support dynamic IT operations.
ECOi-W Free cooling chiller: 24/7 efficiency and reliability for edge data centres
· Low GWP R1234ze refrigerant (GWP=1,37*)
· Capacity from 800 to 1200 kW
· EER up to 5
· Returns to 100% capacity in <120 seconds
· Microchannel coils for free cooling operation up to 10°C outdoor temperature
· Operation -20°C up to 48°C outdoor temperature
· Inverter technology, EC fan, screw compressors
* GWP 1,37 (AR6). Based on the Sixth Assessment Report adopted by the Intergovernmental Panel on Climate Change (IPCC).